Fume Hoods

GT SCIEN fume hoods are designed to provide safe and efficient fume extraction for a variety of laboratory applications. They are constructed of high-quality materials and feature a variety of safety features to protect users from harmful fumes and vapors. Some of the benefits of using GT SCIEN fume hoods include:

  • Safety: GT SCIEN fume hoods are designed to protect users from harmful fumes and vapors. They feature a variety of safety features, such as sash stops, airflow alarms, and emergency shutdown systems.
  • Efficiency: GT SCIEN fume hoods are designed to efficiently remove fumes and vapors from the laboratory. They feature a variety of design features that help to maximize airflow and minimize energy consumption.
  • Versatility: GT SCIEN fume hoods are available in a variety of sizes and configurations to meet the needs of different laboratory applications.
  • Durability: GT SCIEN fume hoods are constructed of high-quality materials that are designed to withstand the rigors of everyday laboratory use.
  • Ease of use: GT SCIEN fume hoods are designed to be easy to use and maintain. They feature a variety of user-friendly features, such as easy-to-clean surfaces and intuitive controls.

GT SCIEN fume hoods are the perfect choice for laboratories that are looking for a safe, efficient, and versatile fume hood.

Here are some of the key features of GT SCIEN fume hoods:

  • Durable construction: GT SCIEN fume hoods are constructed of high-quality materials, such as stainless steel and epoxy-coated steel.
  • Easy to use: GT SCIEN fume hoods feature a variety of user-friendly features, such as easy-to-clean surfaces and intuitive controls.
  • Safe and efficient fume extraction: GT SCIEN fume hoods are designed to efficiently remove fumes and vapors from the laboratory. They feature a variety of design features that help to maximize airflow and minimize energy consumption.
  • Variety of sizes to fit your needs: GT SCIEN fume hoods are available in a variety of sizes to meet the needs of different laboratory applications.

If you are looking for a high-quality, safe, and efficient fume hood, then GT SCIEN is the perfect choice for you.

Types of Fume Hoods

If you work with chemicals, it is crucial to invest in a ventilation system to keep toxic fumes out of the air. Fume hoods are essential when working with gases, vapors, or dust that are hazardous in the event of exposure. They protect you from breathing in particles that can lodge in the lungs or enter the bloodstream.

Safety Features of GT SCIEN Fume Hoods:

  • Protection from Harmful Fumes: GT SCIEN fume hoods effectively remove harmful fumes, vapors, and dust from the laboratory environment, safeguarding users from potential respiratory hazards.

  • Explosion Protection: The safety glass in GT SCIEN fume hoods is designed to “spider” instead of shattering in the event of an explosion, minimizing the risk of injury and protecting users from flying glass and chemicals.

  • Spill Containment: Most GT SCIEN fume hoods include spill-containment features, which are particularly important when working with exceptionally hazardous materials. These features prevent spills from spreading and contaminating the work area.

Choosing the Right GT SCIEN Fume Hood:

The type of fume hood you need depends on the specific chemicals you are working with and the nature of your experiments. GT SCIEN offers a wide range of fume hoods to meet the needs of various laboratory applications.

Considerations for Selecting the Right Fume Hood:

  • Chemical Compatibility: Ensure the fume hood materials are compatible with the chemicals you will be using.

  • Fume Extraction Capacity: Choose a fume hood with sufficient airflow capacity to effectively remove the fumes generated from your experiments.

  • Work Area Size: Select a fume hood that provides adequate workspace for your equipment and procedures.

GT SCIEN: Your Trusted Partner for Laboratory Safety

GT SCIEN is a leading manufacturer of high-quality fume hoods, providing laboratories with essential safety solutions for over a decade. Their fume hoods are designed to meet the strictest safety standards and offer unparalleled protection for laboratory personnel.

Invest in a GT SCIEN fume hood today to safeguard your health and well-being while conducting laboratory experiment

All-in-one Fume Hood

An all-in-one fume hood is a hood that sits on a work surface approximately 36” above the floor. Along with the hood, it comes with supporting base cabinet, a work surface, and an exhaust blower.

Benchtop Fume Hood

A bench-top fume hood is a hood that sits on a work surface approximately 36” above the floor. Along with the hood, you will need a supporting base, a work surface, and an exhaust blower.

Double-faced Fume Hood

A double-faced fume hood is most ideal for demonstrations. It has entrances on both sides and allows for 360-degree viewing. This type of fume-hood can come as a typical bench-top or wall installation or as a portable unit. These are usually in classrooms or laboratories where teaching demonstrations are frequent.

 

Floor Mounted Fume Hood

It resembles a small room, allowing you to work inside the space. This is ideal when you may need to use oversized tools or equipment, such as drums, processing units or robots while working with toxic chemicals. The large doors allow you to roll large apparatus or tables into the area as needed. These fume hoods can range in size depending on your needs but are generally the size of a small closet. Standard models range from 6 to 24 feet wide, 7 to 16 feet high, and 4 to 8 feet deep. However, these can be custom-made to fit your desired dimensions.

Ductless Fume Hood

Ductless fume hoods are designed to protect personnel by filtering out dangerous fumes and vapors so that air can be safely recycled back into the work space in an energy-efficient way. These exhaust hoods are fitted with fans that force the air in a specific direction where it has to pass through several types of carbon filters including HEPA filters where pollution molecules are captured. Giving a high protection performance and biological safety, the ductless hood protects the operator from generated gases. Without the additional ducting system requirement, these enclosures are more mobile and flexible for positioning.

Floor Mounted Fume Hoods or Walk-in Fume Hoods

GT SCIEN floor mounted fume hoods, also known as walk-in fume hoods, are designed to provide safe and efficient fume extraction for large-scale experiments. They are ideal for applications where large equipment, such as distillation units or drums, need to be used inside the hood.

GT SCIEN floor mounted fume hoods are constructed of high-quality materials and feature a variety of safety features to protect users from harmful fumes and vapors. They are also designed to be easy to use and maintain.

Some of the benefits of using GT SCIEN floor mounted fume hoods include:

  • Safety: GT SCIEN floor mounted fume hoods are designed to protect users from harmful fumes and vapors. They feature a variety of safety features, such as sash stops, airflow alarms, and emergency shutdown systems.
  • Efficiency: GT SCIEN floor mounted fume hoods are designed to efficiently remove fumes and vapors from the laboratory. They feature a variety of design features that help to maximize airflow and minimize energy consumption.
  • Versatility: GT SCIEN floor mounted fume hoods are available in a variety of sizes and configurations to meet the needs of different laboratory applications.
  • Durability: GT SCIEN floor mounted fume hoods are constructed of high-quality materials that are designed to withstand the rigors of everyday laboratory use.
  • Ease of use: GT SCIEN floor mounted fume hoods are designed to be easy to use and maintain. They feature a variety of user-friendly features, such as easy-to-clean surfaces and intuitive controls.

GT SCIEN floor mounted fume hoods are the perfect choice for laboratories that are looking for a safe, efficient, and versatile fume hood for large-scale experiments.

Here are some of the key features of GT SCIEN floor mounted fume hoods:

  • Durable construction: GT SCIEN floor mounted fume hoods are constructed of high-quality materials, such as stainless steel and epoxy-coated steel.
  • Easy to use: GT SCIEN floor mounted fume hoods feature a variety of user-friendly features, such as easy-to-clean surfaces and intuitive controls.
  • Safe and efficient fume extraction: GT SCIEN floor mounted fume hoods are designed to efficiently remove fumes and vapors from the laboratory. They feature a variety of design features that help to maximize airflow and minimize energy consumption.
  • Variety of sizes to fit your needs: GT SCIEN floor mounted fume hoods are available in a variety of sizes to meet the needs of different laboratory applications.

GAHP-W115

GAHP-W118

GAHP-W121

GAHP-W124

CategoryGAHP-W115GAHP-W118GAHP-W121GAHP-W124
Dimensions
(W x D x H, mm)
Exterior1500 x 800 x 23501800 x 800 x 23502100 x 800 x 23502400 x 800 x 2350
Interior1300 x 600 x 18001600 x 600 x 18001900 x 600 x 18002100 x 600 x 1800
valveGas1111
Water2222
Air1111
Electrical Outlets4444
Lighting (36W)1122
Interior materialsPhenolaminate 4T
Exhaust vent200ø / 250ø / 300ø
Voltage120 Single Phase – 220V Single Phase – 380V Three-Phase