Toxic Gas Purifiers and Fume Extractors
Equipped with advanced AIoT technology, our toxic gas purifier effectively captures and traps a multitude of harmful gaseous air pollutants, fostering a safe and healthy work environment for researchers. Seamlessly integrated with SmartLab Sensor AI, this intelligent system autonomously detects and eliminates toxic gases within expansive laboratory settings, providing peace of mind and ensuring the well-being of researchers.
Toxic gas purifiers and fume extractors are essential pieces of equipment for many workplaces, especially those where hazardous chemicals are used. These devices play a crucial role in protecting workers from harmful airborne contaminants and ensuring a safe working environment.
Benefits of Toxic Gas Purifiers
Toxic gas purifiers are designed to remove harmful gases from the air, providing several benefits for workplaces:
Improved worker health: By eliminating toxic gases, purifiers protect workers from respiratory problems, headaches, dizziness, and other health issues caused by exposure to hazardous chemicals.
Reduced risk of accidents: Toxic gases can be flammable or explosive, increasing the risk of accidents. Purifiers help to mitigate these risks by removing these dangerous substances from the air.
Compliance with regulations: Occupational Safety and Health Administration (OSHA) and other regulatory agencies have established permissible exposure limits (PELs) for various toxic gases. Purifiers help workplaces comply with these regulations and avoid fines or penalties.
Peace of mind: Knowing that workers are protected from toxic gases provides peace of mind for employers and employees alike.
Benefits of Fume Extractors
Fume extractors are specifically designed to remove fumes, smoke, and dust from the air, offering several advantages for workplaces:
Improved air quality: Fume extractors effectively remove contaminants from the air, creating a healthier and more comfortable working environment.
Reduced odor: Fume extractors help to eliminate unpleasant odors caused by chemicals, welding fumes, and other processes.
Enhanced visibility: Fumes and smoke can reduce visibility, increasing the risk of accidents. Fume extractors help to maintain clear visibility, improving safety and productivity.
Protection of equipment: Fume extractors prevent corrosive fumes and dust from damaging sensitive equipment.
Compliance with regulations: OSHA and other regulatory agencies have established PELs for various airborne contaminants. Fume extractors help workplaces comply with these regulations and avoid fines or penalties.
Applications of Toxic Gas Purifiers and Fume Extractors
Toxic gas purifiers and fume extractors are used in a wide range of workplaces, including:
Laboratories: Chemical laboratories generate various toxic gases, and purifiers are essential for protecting researchers.
Industrial settings: Manufacturing, welding, and other industrial processes produce hazardous fumes and gases, requiring fume extractors to maintain a safe environment.
Healthcare facilities: Hospitals and laboratories use purifiers to remove anesthetic gases and other airborne contaminants.
Construction sites: Fume extractors are used to remove dust, fumes, and gases generated during construction activities.
Auto repair shops: Fume extractors are used to remove exhaust fumes and other contaminants from garages and repair bays.
Portable Toxic Gas Purifiers and Mobile Fume Extractors (Movable Type)
TOGA-M01AI
Model | TOGA-M01AI |
Dimensions Exterior (W x D x H, in/mm) | 18 x 18 x 38 / 450 x 450 x 950 |
Applicable Room Area | – |
Air Volume | 353 cfm/10 cmm |
Controller | 5 Levels |
LSPMS Connect | Y |
Filter Replacement Period (Recommended) | 1 year (actual filter life may vary according to use, concentration and quantities of reagents stored) |
Purification Efficiency | Over 99.7% of toxic gases, VOC’s, acids, bases, and foul odors |
Noise | < 50dB |
Voltage, Frequency | AC120V, 50/60Hz |
Power Consumption | 169W |
Weight (lbs/kg) | 177 / 80 |
TOGA-M01MAC
Model | TOGA-MAC1-AI |
Dimensions Exterior (W x D x H, in/mm) | 18 x18 x 41 / 450 x 450 x 1035 |
Applicable Room Area | – |
Air Volume | 353 cfm/10 cmm |
Controller | 5 Levels |
LSPMS Connect | Y |
Filter Replacement Period (Recommended) | 1 year (actual filter life may vary according to use, concentration and quantities of reagents stored) |
Purification Efficiency | Over 99.7% of toxic gases, VOC’s, acids, bases, and foul odors |
Noise | < 50dB |
Voltage, Frequency | AC120V, 50/60Hz |
Power Consumption | 174W |
Weight | 70kg |
TOGA-M01D
Model | TOGA-M01D |
Dimensions Exterior (W x D x H, in/mm) | 16 x 16 x 38 / 400 x 400 x 960 |
Applicable Room Area | – |
Air Volume | 353 cfm/10 cmm |
Controller | 5 Levels |
LSPMS Connect | – |
Filter Replacement Period (Recommended) | 1 year (actual filter life may vary according to use, concentration and quantities of reagents stored) |
Purification Efficiency | Over 99.7% of toxic gases, VOC’s, acids, bases, and foul odors |
Noise | < 50dB |
Voltage, Frequency | AC120V, 50/60Hz |
Power Consumption | 169W |
Weight | 69kg |
Stationary Toxic Gas Purifiers (Stand Type)
TOGA-S02AI
Model | TOGA-S02AI |
Dimensions Exterior(W x D x H, in/mm) | 18 x 18 x 73 / 450 x 450 x 1835 |
Applicable Room Area | 852.5 sq ft/79.2 sq m |
Air Volume | – |
Controller | 5 Levels |
LSPMS Connect | Y |
Filter Replacement Period (Recommended) | 1 year (actual filter life may vary according to use, concentration and quantities of reagents stored) |
Purification Efficiency | Over 99.7% of toxic gases, VOC’s, acids, bases, and foul odors |
Noise | < 50dB |
Voltage, Frequency | AC120V, 50/60Hz |
Power Consumption | 169W |
Weight (lbs/kg) | 309 / 140 |
TOGA-S02D-AI
Model | TOGA-S02D-AI |
Dimensions Exterior(W x D x H, in/mm) | 20 x 18 x 73 / 500 x 450 x 1770 |
Applicable Room Area | 852.5 sq ft/79.2 sq m |
Air Volume | – |
Controller | 5 Levels |
LSPMS Connect | Y |
Filter Replacement Period (Recommended) | 1 year (actual filter life may vary according to use, concentration and quantities of reagents stored) |
Purification Efficiency | Over 99.7% of toxic gases, VOC’s, acids, bases, and foul odors |
Noise | < 50dB |
Voltage, Frequency | AC120V, 50/60Hz |
Power Consumption | 169W |
Weight (lbs/kg) | 287 / 130 |
TOGA-S02D
Model | TOGA-S02D |
Dimensions Exterior (W x D x H, mm) | 500 x 450 x 1770 |
Applicable Room Area | 852.5 sq ft/79.2 sq m |
Air Volume | – |
Controller | 5 Levels |
Reagent Management System | – |
Filter Replacement Period (Recommended) | 1 year (actual filter life may vary according to use, concentration and quantities of reagents stored) |
Purification Efficiency | Over 99.7% of toxic gases, VOC’s, acids, bases, and foul odors |
Noise | < 50dB |
Voltage, Frequency | AC120V, 50/60Hz |
Power Consumption | 169W |
Weight | 110kg |